Hot Product

Product drawing»

Structural drawing»

You are here:  

Valve test bench setup, quick coupling

2010-11-05

Commercially available coupler that I can use on 2"npt thread (internal and external) for my hydro shell test at 7500psi and a gas closure test at 80-100psi? We are introducing a low cost ball valve, have very tight margins, but of course need to follow the testing laid out in b16.34 and api598. trying to reduce labour costs by having an easy "drop and clamp" in place for testing that would not invalidate the tests.The material of construction? Having worked in the fittings and valve industry I never seen any testing setup for anything under 6" that used anything other that a pneumatic or hydraulic clamping device where testing fluid was introduced through one of the seating pads. I can understand where you are coming from with the 750 psig test requirement Thread make up is going to be a bear if you are using NPT threads in a make and break situation. need to test each valve, and for the local regulating body only the shell test of 150% of working pressure is needed. but to test to ap598 we need a closure test to both sides of the ball valve. 0 leakage for both tests.

MORE NEWS

  • Closed center valve problem
  • Cv and mass flow rate
  • Low pressure check valve on a TANK
  • HYSYS Selection of Property Package
  • Shanghai MeiYan Yi Pump & Valve Co., Ltd.
    MeiYan Yi solenoid valve Contact MeiYan Yi
    Shanghai Enine Pump & Valve Co., Ltd.
    Enine solenoid valve Contact Enine
    Shanghai Saitai Pump & Valve CO., Lid.
    Saitai solenoid valve Contact Saitai
    Shanghai Fengqi Industrial Development Co., Ltd.
    FengQi solenoid valve Contact FengQi